DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

SSH EN 253:2009

District heating pipes - Preinsulated bonded pipe systems for directly buried hot water networks - Pipe assembly of steel service pipe, polyurethane thermal insulation and outer casing of polyethylene

Dec 22, 2009
95.99 Withdrawal of Standard   Oct 30, 2013

General information

95.99     Oct 30, 2013

DPS

DPS/KT 269

European Norm

23.040.07     23.040.10  

English  

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This European Standard specifies requirements and test methods for straight lengths of prefabricated thermally insulated pipe-in-pipe assemblies for directly buried hot water networks, comprising a steel service pipe from DN 15 to DN 1200, rigid polyurethane foam insulation and an outer casing of polyethylene. The pipe assembly may also include the following additional elements: measuring wires, spacers and diffusion barriers.
This standard applies only to insulated pipe assemblies, for continuous operation with hot water at various temperatures up to 120 °C and occasionally with a peak temperature up to 140 °C.
The estimation of expected thermal life with continuous operation at various temperatures is outlined in Annex B.

Life cycle

PREVIOUSLY

WITHDRAWN
SSH EN 253:2003

NOW

WITHDRAWN
SSH EN 253:2009
95.99 Withdrawal of Standard
Oct 30, 2013

REVISED BY

WITHDRAWN
SSH EN 253:2009+A1:2013

Related project

Adopted from EN 253:2009