DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

SSH EN ISO 10211:2017

Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations (ISO 10211:2017)

Mar 28, 2018

General information

60.60     Jan 26, 2018

DPS

DPS/KT 67

European Norm

91.120.10  

English  

Buying

Published

Language in which you want to receive the document.

Scope

ISO 10211:2017 sets out the specifications for a three-dimensional and a two-dimensional geometrical model of a thermal bridge for the numerical calculation of
- heat flows, in order to assess the overall heat loss from a building or part of it, and
- minimum surface temperatures, in order to assess the risk of surface condensation.
These specifications include the geometrical boundaries and subdivisions of the model, the thermal boundary conditions, and the thermal values and relationships to be used.
ISO 10211:2017 is based upon the following assumptions:
- all physical properties are independent of temperature;
- there are no heat sources within the building element.
ISO 10211:2017 can also be used for the derivation of linear and point thermal transmittances and of surface temperature factors.
NOTE Table 1 in the Introduction shows the relative position of ISO 10211:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

Related directives

Directives related to this standards.

2010/31/EU

Directive 2010/31/eu of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings (recast)

Life cycle

NOW

PUBLISHED
SSH EN ISO 10211:2017
60.60 Standard published
Jan 26, 2018

Related project

Adopted from EN ISO 10211:2017