This European Standard specifies requirements for the execution, i.e. the manufacture and the installation, of cold-formed structural steel members and sheeting and cold-formed structures for roof, ceiling, floor, wall and cladding applications.
This European Standard applies to structures designed according to the EN 1993 series.
This European Standard applies to structural members and sheeting to be designed according to EN 1993-1-3.
This European Standard may be used for structures designed according to other design rules provided that conditions for execution comply with them and any necessary additional requirements are specified.
This European Standard also specifies requirements for the execution i.e. the manufacture and the installation of structures made from cold formed profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading or seismic loading conditions and their documentation.
This European Standard covers sheeting of structural classes I and II according to EN 1993-1-3 used in structures.
This European Standard covers structural members of all structural classes according to EN 1993-1-3.
Structural sheeting are understood here to be:
- profiled sheet, such as trapezoidal, sinusoidal or liner trays, or
Structural members are understood here to be:
- members (linear profiled cross sections) that are produced by cold forming.
This European Standard also covers:
- not welded built-up sections;
- cold-formed hollow sections including the welding of the longitudinal seam, not covered by EN 10219-1;
- perforated, punctured and micro profiled sheeting and members;
NOTE 1: Welded built-up sections, are not covered, the execution provisions are given in EN 1090–2.
This European Standard also covers spacer constructions between the outer and inner or upper and lower skins for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as all are involved in load transfer. This European Standard covers steel profiled sheeting for composite floors, e.g. during installation and in stage of pouring concrete. Composite structural members where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard.
This European Standard does not cover the necessary analyses and detailing and execution rules for thermal insulation, moisture protection, noise control and fire protection.
This European Standard does not cover regulations of roof cladding and wall cladding, produced by traditional plumber methods or tinsmith methods.
This European Standard does not cover detailed requirements for water tightness or air permeability resistance and thermal aspects of sheeting.
PUBLISHED
SSH EN 10346:2015
PUBLISHED
SSH EN 13523-10:2017
PUBLISHED
SSH EN 13523-1:2017
PUBLISHED
SSH EN 10152:2017
PUBLISHED
SSH EN 13523-8:2017
PUBLISHED
SSH EN 13523-21:2017
PUBLISHED
SSH EN 10204:2005
PUBLISHED
SSH EN 10162:2003
PUBLISHED
SSH EN 13523-6:2002
PUBLISHED
SSH EN 10143:2006
WITHDRAWN
SSH EN 13523-19:2011
PUBLISHED
SSH EN 1090-1:2009+A1:2011
PUBLISHED
SSH EN 13523-26:2014
PUBLISHED
SSH EN 13523-7:2014
PUBLISHED
SSH EN 1090-4:2018
60.60
Standard published
Feb 24, 2020
PUBLISHED
SSH EN 1090-2:2018